| Home > Specifications & Details > Fixed Windows |
![]() |
|||||
| Nonoperable companion units (frame dimensions*) | |||||
| Rectilinear (maximum of 50 square ft) | 8" (203) | 10' 0" ** (3048) | 8" (203) | 10' 0" ** (3048) | |
| Curve Top | 1' 0" (305) | 9' 0" (2743) | 10 1/2" (267) | 8' 0" (2438) | |
| *Opening = frame + 3/4" Sizes listed in parenthesis denote millimeters. Larger & smaller sizes available on custom basis. See your local Pella sales representative for more information. ** Maximum of 8'0" for fixed windows with removable exterior glass stops. |
|||||
| Woods | |||||
| Pine | |||||
| Mahogany | |||||
| Alder | |||||
| Douglas Fir | |||||
| Grilles | |||||
| Historical grilles (permanent interior and exterior) | |||||
| Removable interior grilles (wood) | |||||
| Grilles-between-the-glass (White interior, exterior finish matches aluminum-cladding color) |
|||||
![]() |
|||||
| Clear Insulating Glass (IG) | |||||
| Argon-filled, Low-E IG | |||||
| Tinted and Reflective | |||||
| Laminated Glass | |||||
| Impact Resistant | |||||
| Spandrel Panels | |||||
![]() |
|||||
| NFRC U-value Total Unit (48" x 48") | 0.29 - 0.51 | 0.31 - 0.53 | |||
| Design Pressure* (psf) | 20 - 90 | 30 - 90 | |||
| Structural Test Pressure (psf) | 30 - 135 | 45 - 135 | |||
| Water Penetration | none @ 15 psf | none @ 15 psf | |||
| Air Infiltration (@ 1.57 psf) | 0.05 cfm | 0.05 cfm | |||
| * Performance class and grade rating and related hallmark certification apply to single units only with appropriate glass options and not the combined or composite units.
Enhanced performance is available with Pella’s line of Advanced Performance products. Ask your local Pella architectural consultant for more information. |
|||||
![]() |
|||||
| Winter NFRC U-value | 0.25 - 0.51 | 0.25 - 0.51 | |||
| Solar Heat Gain Coefficient | 0.32 - 0.79 | 0.32 - 0.79 | |||
| Shading Coefficient | 0.37 - 0.91 | 0.37 - 0.91 | |||
| % UV Transmission | 7 - 62 | 7 - 62 | |||
| LBL Fading Damage*** | 0.18 - 0.64 | 0.18 - 0.64 | |||
| % Visible Light Transmission | 40 - 83 | 40 - 83 | |||
| Performance numbers based on standard glass options. | |||||
![]() |
|||||
| STC Rating | 28 - 36 | 28 - 36 | |||
| OITC Rating | 24 - 32 | 24 - 32 | |||
| ** Performance numbers based on standard glass options. *** Developed by Lawerence Berkeley Laboratories, the LBL damage function is a better predictor of fading damage than UV transmission. Lower values indicate less fading potential. (NOTE: This value does not consider visible light.) |
| ©2008 Pella Corporation. All Rights Reserved. Privacy Policy. | ![]() |